62290 - IONIZER, OVERHEAD, ZERO VOLT, 3 FAN, 120 V, US PLUG
|
|
|
|
|
|
|
- Best Overhead Ionizer Now Available from Semtronics
- Low Balance (Offset Voltage)
- Balance ±3 volt, typically; ±5 volts maximum controlled via Semtronics patented Auto-Balancing Sense Feedback
- Fast Discharge Time
Tested at 3.1 seconds Neutralization Discharge Time under fan 1,000 volts to 100 volts per ESD S3.1 (18" under fans)
- Data Acquisition
Data acquisition via RS485 to computer recording levels of performance at all times
- Calibration
Easy to adjust or calibrate with control buttons on the unit, no adjustments tools are needed. Optional battery operated hand-held Infrared Remote Control to adjust offset voltage (balance), and maintenance and alarm levels (using Charged Plate Monitor)
- Overhead installation with two 9-speed fans
- Up to 124 units can be daisy-chained into one serial port
- Optional Remote Control Available
Model 62260 I/R remote control can be used to remotely adjust balance, fan speed and alarm settings up to 9 feet away.
- CSA Approved
- Made in America
“Necessary non-conductors in the environment cannot lose their electrostatic charge by attachment to ground. Ionization systems provide neutralization of charges on these necessary non-conductive items (circuit board materials and some device packages are examples of necessary non-conductors). Assessment of the ESD hazard created by electrostatic charges on the necessary nonconductors in the work place is required to ensure that appropriate actions are implemented, commensurate with risk to ESDS [ESD sensitive] items”. (ANSI/ESDS20.20-2007 Foreword)
“In order to mitigate field-induced CDM [Charged Device Model] damage, the ESD program shall include a plan for the handling of process-required insulators. If the field exceeds 2,000 volts/inch, steps shall be taken to either: A) Separate the insulator from the ESD-sensitive device by a distance of 30 cm (12 inches); or B) Use ionization or other charge mitigating techniques to neutralize the charge.” (ANSI/ESDS20.20-2007 section 8.3)
“The primary method of static charge control is direct connection to ground for conductors, static dissipative materials, and personnel. A complete static control program must also deal with isolated conductors that cannot be grounded, insulating materials (e.g., most common plastics), and moving personnel who cannot use wrist or heel straps or ESD control flooring and footwear. Air ionization is not a replacement for grounding methods. It is one component of a complete static control program. Ionizers are used when it is not possible to properly ground everything and as backup to other static control methods. In clean rooms, air ionization may be one of the few methods of static control available.” (ESD Handbook TR20.20 Ionization, section 5.3.6.1)
“All ionization devices will require periodic maintenance for proper operation. Maintenance intervals for ionizers vary widely depending on the type of ionization equipment and use environment. Critical clean room uses will generally require more frequent attention. It is important to set-up a routine schedule for ionizer service. Routine service is typically required to meet quality audit requirements.” (ESD Handbook TR 20.20 section 5.3.6.7 Maintenance / Cleaning)
|
|